金彩汇

Current Location:Home > Product > High frequency induction heating series > High frequency heating machine

2018-10-26 10:24:07

Share
  • Share to WeChat Moments

RAZ-200KW high frequency heating machine

  • Description

1. Industry application:



1. Welding

1) Welding of carbide tools. Such as turning tools, milling cutters, reamer.

金彩汇2) Welding of diamond bits. Such as diamond saw blades, abrasive tools, sawtooth welding. Welding of drill bits for prospecting, such as welding of a sub-drill and a claw bit.

金彩汇3) Composite welding of metal materials such as brass, copper, stainless steel, etc.

金彩汇2. Heat fitting and heat fusion equipment

金彩汇1) The heating of the motor rotor and the water pump shell, and the heating of the bearing sleeve. Thermal fusion of plastic handle of tableware, etc.

2) Heating lamination of aluminum-plastic pipes, cables and wires; aluminum foil sealing used in food, beverage, and pharmaceutical industries, preheating expansion of metals, etc.

3. Quenching

Surface, inner hole, partial or overall quenching of various hardware tools, electric, hydraulic, pneumatic components, auto parts, motorcycle parts and other mechanical metal parts

金彩汇4. Annealing equipment

It can perform overall or partial annealing treatment for various mechanical parts, and tensile annealing for stainless steel products within a diameter of 50

1) Heat the metal material for stretching, molding, embossing, etc. Such as steel pipe stretching, pipe bending, head smashing; iron wire, steel wire heating nailing

金彩汇3) Heating and annealing metal materials. Such as steel pipe drawing, pipe bending; smashing head, iron wire, steel wire heating nails, stainless steel products

金彩汇5. Smelting

1) Melting gold/copper/silver: 1-5kg

2) molten steel/aluminum: 1-3kg


2. Main features:

1. Simple installation, only need to connect electricity and water to use, no need for special installation

金彩汇2. Easy to operate: you can learn in a few minutes

3. Quick start: the heating can be started after the water is turned on

4. Less power consumption: Compared with old-fashioned high-frequency equipment, it saves power, and the smaller the workpiece, the less power consumption

金彩汇5, the effect is good: the heating is very uniform, the temperature rises quickly, and the oxide layer is less.

金彩汇6. Adjustable power: adjustable output power

金彩汇7. Full protection: with overvoltage, overcurrent, overheating, water shortage and other alarm indications, and automatic control and protection


 

3. Operation steps

RAG-15KW高频加热机剪刀淬火

1. Water: Start the water pump and observe whether the water flow at the water outlet is normal.

金彩汇2. Power on: first close the knife, then turn on the air switch at the back of the machine, and then turn on the power switch on the control board.

金彩汇3. Setting: Select the operation mode (full automatic, semi-automatic, manual and foot control) according to your needs. When automatic and semi-automatic control, you need to set the heating time, holding time and cooling time (each time cannot be set to 0, otherwise it will not work properly). automatic cycle). Before using it for the first time and before you are proficient, you should use manual or foot control.

金彩汇4. Start: Before each start, the heating power potentiometer should be adjusted to the minimum as much as possible, and then slowly adjust the temperature to the required power after starting. Press the start button to start the machine, at this time the heating indicator on the panel is on, and there will be a sound of normal work and the simultaneous flashing of the work light.

5. Observation and temperature measurement: During the heating process, visual inspection is mainly used to determine when to stop heating based on experience. Inexperienced operators can use a thermostat to detect the temperature of the workpiece.

6. Stop: When the temperature reaches the requirement, press the stop button to stop heating. You can start it again after replacing the workpiece.

金彩汇7. Shutdown: The machine can work continuously for 24 hours. The power switch should be turned off when not in use, and the knife or the air switch at the rear of the machine should be turned off when not in use for a long time. When shutting down, the power should be cut off first and then the water should be cut off, so as to facilitate the heat dissipation inside the machine and the heat of the induction coil. Note: The machine should not work without load as much as possible, let alone run without load for a long time, otherwise, it will affect the performance and stability of the machine!


 

4. Precautions for use

RAG-15KW高频加热机

1. In order to prevent electric shock, please ensure that the electrical specifications of the casing are reliably grounded.

金彩汇2. The removal and installation of the sensor must be carried out after the heating stops.

金彩汇3. Strictly implement the principle of water first and then electricity. Water shortage is strictly prohibited during the working process. The water quality and pressure of the cooling water inside the equipment and the sensor must meet the requirements of Table 2. In order to avoid blocking the cooling pipeline, if the water supply is supplied by a water pump, please install a filter at the water inlet of the water pump. The cooling water temperature should not be higher than 45°C, and the water flow rate should be 10T/h (softened water is recommended)

4. The equipment should be protected from sunlight, rain, moisture, dust, etc. When repairing or maintaining the equipment is required, it must be done one hour after the power is turned off.

金彩汇5. In-machine cleaning method Blown with compressed air or blower every week. The circuit board is cleaned with a brush and then blown clean.

金彩汇6. Ordinary users should clean the waterway of the machine with a special descaling agent (available from our company) every 4 months. When the machine frequently alarms the water temperature, or observes that the water flow of the water outlet decreases significantly, it should be cleaned immediately.

7. The sensor should be kept clean to prevent short circuit between turns.

8. This device cannot use single-turn inductors. Otherwise, the device may be damaged due to too small inductive reactance. In special cases, please consult the manufacturer.

9. When replacing the sensor, the contact surface between the sensor connection board and the transformer should be cleaned with sandpaper to maintain good electrical conductivity.

 

5. Technical parameters

model

RAG-15KW


model

RAZ-200KW

power

15KW


power

 25KW

Input current

23A


Input current

32A

Oscillation frequency

30-100KHZ


Oscillation frequency

30-100KHZ

Input voltage

单相220V


Input voltage

three phase380V

molten gold

1-3kg


molten gold

1-5kg

volume(cm)

42*20*36


volume(cm)

57*22*46

weight(KG)

20


weight(KG)

28

 

6. Troubleshooting and troubleshooting

Fault

possible reason

Solution

After turning on the power switch, the "Power" indicator does not light up

金彩汇1 The panel power switch is in poor contact

金彩汇21P air circuit breaker trip

金彩汇3 Phase loss

金彩汇1 Close and open, repeat several times

21P air open to send on

3 Check the power supply voltage

After stepping on the foot switch, the work light does not light up

1 Foot switch lead off

金彩汇2 The AC contactor is not closed or the contact is poor

3 Poor contact of the sensor

1 Check the foot switch lead wire or AC contactor or sensor

Adjust the panel power to the maximum, no current indication or the current is too small

1 The number of turns of the inductor is too much or the load is too heavy

2 sensor short circuit

3 Poor contact at the sensor

4 half bridge work

金彩汇1 Reconfigure the sensor

金彩汇2 reboot after separation and it works fine

3 Grinding or pickling at joints

金彩汇4 Contact the manufacturer

The workpiece cannot be heated after being placed

1 The external power supply capacity is small or the wire is too thin

2 phase loss

金彩汇3 The number of turns of the inductor is too much or the load is too heavy

金彩汇4 half bridge work

1 Increase the power capacity

金彩汇2 Check the three-phase power supply

金彩汇3 Reconfigure the sensor

金彩汇4 Contact the manufacturer

Overcurrent alarm

金彩汇1 The contact of the sensor is bad or short circuit

金彩汇2 The contacts of the AC contactor are in poor contact

3 Too many or too few turns of the inductor

4 ignition at the external power connector

5 Poor contact of high-frequency cables

6 Power board failure

金彩汇7 There is a spark inside

金彩汇8 The resonant transformer is bad

1 Check the sensor, high frequency cable, external power supply

2 Replace the AC contactor

3 Reduce the number of inductor turns

金彩汇4 Check the power tube

water pressure alarm

金彩汇1 The water pressure is too low

2 limescale clogging

3 The water pressure switch is broken

金彩汇1 Increase the water pressure

金彩汇2 Clean the limescale

金彩汇3 Replace the water pressure switch

water temperature alarm

1 The water temperature is too high

2 The water flow is too small

3 water pipe blockage

4 Too much scale inside

金彩汇1 Change the cooling water

金彩汇2 Increase the water pump or water pressure

3 Clean with descaling agent 1 40

4 Replace the water temperature relay

Recommended Products